| Input Voltage Range | 18 VDC – 150 VDC (24V/48V/80V/96V/110V Nominal) | 200 VDC – 900 VDC (400V/800V Battery Bus) | Customized to customer specification |
| Output Options | 12 VDC, 24 VDC, 48 VDC (Regulated) | 12 VDC, 24 VDC, 48 VDC (Low-Noise Output) | Multi-channel / Adjustable voltage outputs |
| Galvanic Isolation | Yes (Input / Output / CAN isolated) | Reinforced High-Voltage Isolation (>3.75 kVAC) | Up to 5 kVAC Isolation barrier |
| CAN Protocols | CAN 2.0B, SAE J1939, CANopen | SAE J1939, CANopen, ISO 11898, UDS | Custom CAN matrix / Proprietary frames |
| Thermal Management | Baseplate Contact Cooling (No fan needed) | Baseplate Contact Cooling / Cold-Plate Ready | Contact Cooling / Integrated Heat Sink |
| Protection Ratings | IP65 / IP67 Potted Housing | IP67 / IP6K9K Hermetically Sealed Potted | Tailored IP enclosure mechanics |
| Compliance Standards | EN 61000-6-2, EN 61000-6-4, ISO 13766 | ECE R10, EN 50155 (Rail), ISO 26262 Ready | ECE R10, EN 45545-2, Customer Specific |